State-Owned Enterprise Partner | National Lab Certified | 24h Response

Engineering-Grade Aerogel Insulation Solutions

650°C Max Service Temp
0.015 W/m·K Conductivity
80% Lighter Than Fiber Wool
20+ Year Lifespan
Scroll

How It Works

1

Submit Parameters

Fill in your project requirements and operating conditions through our simple form.

2

Expert Calculation

Our certified engineers calculate optimal insulation solutions using national lab-verified data.

3

Get Results

Receive verified calculation results and product recommendations via email within 24 hours.

Professional Calculation Services

Certified engineering calculations for every industrial insulation scenario

Pipe Insulation Calculation

Thermal insulation thickness and material calculations for industrial piping systems — steam, hot oil, and process lines.

Submit Request

Equipment Insulation Calculation

Optimized insulation design for vessels, tanks, reactors, and other industrial equipment.

Submit Request

Cryogenic Insulation Calculation

Specialized cold-insulation design for LNG, liquid nitrogen, and other sub-zero applications.

Submit Request

Acoustic Insulation Calculation

Noise reduction engineering for industrial environments, compressor stations, and piping systems.

Submit Request

Carbon Emission Analysis

Energy savings and carbon reduction calculations for insulation improvement projects.

Submit Request

Trusted Engineering, Verified Results

National Lab Verification

All calculations verified through CNAS-certified laboratories. Every result is traceable and reliable.

24-Hour Turnaround

Calculation results delivered within 24 hours. Priority service available for urgent projects.

Zero False Data

Product parameters strictly follow national standards. No inflated claims, no false data — guaranteed.

Aerogel Products

All parameters verified. All standards met. No compromise on quality.

Aerogel Rigid Board

Rigid aerogel insulation panel for flat surfaces, walls, and ceilings. Parameters verified per GB/T 34336. certified.

25mm – 100mm λ = 0.018 W/m·K

Aerogel Pipe Insulation

Pre-formed half-shell sections for standard pipe diameters. Custom sizes available. Parameters verified. certified.

DN15 – DN600 Custom OD available

Verified Performance Data

All data per national standards. Test reports available upon request.

Property Test Standard Aerogel Blanket Aerogel Board Unit
Thermal Conductivity (25°C) GB/T 10294 / ASTM C177 0.015 0.018 W/m·K
Service Temperature (max) — 650 500 °C
Bulk Density GB/T 5480 / ASTM C303 150–200 200–250 kg/m³
Flexural Strength GB/T 10699 / ASTM C203 Flexible >0.3 MPa
Hydrophobicity (contact angle) — >150° >140° degrees
Fire Class GB 8624 / EN 13501-1 A1 Non-Combustible —

Ready to Optimize Your Insulation?

Submit your project parameters for a professional calculation.